AFT 06/17/26/27



The thermostats operate according to the liquid expansion principle. For the AFT 06, AFT 17 designs, the set-point adjuster is directly fitted to the actuator; for the AFT 26, AFT 27 designs it is delivered seperately. There are two sensor designs with different time constants.

AFT 06/17/26/27

Technical data



Code No.PN
(bar)
Min. setting temp.
(°C)
Max. setting temp.
(°C)
Capillary length
(m)
Max. sensor temp.
(° C)

AFT 06

065-4390 40-20505150
065-4391 4020905190
065-4392 40401105210
065-4393 40601305230
065-4394 401101805280

AFT 17

065-4400 40-20505150
065-4401 4020905190
065-4402 40401105210
065-4403 40601305230

AFT 26

065-4396 40-20505150
065-4398 40401105210
065-4399 40601305230
065-4428 4020905190

AFT 27

065-4404 40-20505150
065-4405 4020905190
065-4406 40401105210
065-4407 40601305230